{"product_id":"frsky-advanced-engine-suite-ii-aes-ii-multi-functional-engine-management-box","title":"FrSky Advanced Engine Suite II (AES II) Multi-Functional Engine Management Box","description":"\u003ch3\u003e\u003cspan style=\"text-decoration: underline; color: rgb(255, 42, 0);\"\u003e\u003cem\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eAdvanced Engine Suite II (AES II) is a multi-functional management box suitable for application in airplanes equipped with engines.\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThrough the VBAT (XT30\/PWR) power port, users can use the same battery to power all connected devices, eliminating the trouble of providing an independent power supply for the ignition control unit. AES also adopts a safety solution to avoid potential risks caused by interference between the connected ignition and receiver devices.\u003c\/p\u003e\n\u003cp\u003e\u003cimg\u003e\u003cimg\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0683\/5637\/4815\/files\/AES-II-Diagram.png?v=1750379134\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe AES module is equipped with a wealth of sensor interfaces, including 2 sets of 2 RPM sensor ports, 1 flowmeter sensor port, and 7 temperature (4 PT100 type \u0026amp; 3 TEMS Type) sensor ports. In addition, AES also provides 2 AD ports, allowing users to flexibly use different types of AD devices required in your airplane. At the same time, through the FBUS\/S. Port feature of the connected receiver, users can monitor the telemetry data in real-time on the transmitter to know the aircraft’s operating status.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0683\/5637\/4815\/files\/AES-_-2.jpg?v=1750379449\" alt=\"\"\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cem\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDimension: 50×46.4x18mm (L×W×H)\u003c\/li\u003e\n\u003cli\u003eWeight: 53.5g\u003c\/li\u003e\n\u003cli\u003eBattery Voltage Input Range: 4.5-13V\u003c\/li\u003e\n\u003cli\u003eBattery Input Connector: XT30\u003c\/li\u003e\n\u003cli\u003eIGN (Ignition Port) Voltage Output Range: 4.5-13V (Sync with the input voltage settings of VBAT.)\u003c\/li\u003e\n\u003cli\u003eOperating Current: 20mA@5V\u003c\/li\u003e\n\u003cli\u003eSignal Voltage Level\u003cbr\u003e– RPM1\/RPM2 Port: 3V-12V (Requires the driven current＞5mA)\u003cbr\u003e– RPM3\/RPM4 Port: 0 -3.3V (Requires the driven current＞5mA)\u003cbr\u003e– Flow Port: 3.3V\u003cbr\u003e– AD1\/AD2 Port: 0-3.3V\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cem\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIgnition Battery Eliminator Design (Independent battery is NOT needed.)\u003c\/li\u003e\n\u003cli\u003eAnti-interference Capability between Ignition \u0026amp; Receiver Parts\u003c\/li\u003e\n\u003cli\u003e2 Powering Ports for Ignition Kill Switch Unit\u003c\/li\u003e\n\u003cli\u003e4 Ports for RPM Sensors\u003c\/li\u003e\n\u003cli\u003e7 Ports for Temperature Sensors\u003cbr\u003e– 4 Ports for PT100 Type\u003cbr\u003e– 3 Ports for TEMS Type\u003cbr\u003e2 Ports for AD Device\u003cbr\u003e1 Port for Flowmeter Sensors\u003cbr\u003e(Sensors are required to be purchased separately. Sensor options: PT100 Temp Sensor [04100488], TEMS Temp Sensor [04100427], Flowmeter [03040703] )\u003c\/li\u003e\n\u003cli\u003eSignal Input Ports for FBUS\/S.Port (Auto Recognition), SBUS, and PWM\u003c\/li\u003e\n\u003cli\u003e1 IGN LED Port to Indicate Ignition Status\u003c\/li\u003e\n\u003cli\u003e1 Powering Port for Receiver \/ FWUG (Firmware Upgrade Port)\u003c\/li\u003e\n\u003cli\u003e1 Battery Input Port with XT30 Connector\u003c\/li\u003e\n\u003cli\u003eReal-Time Configuration Capability (by S.Port of ETHOS radio or FBUS capable receivers)\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Frsky","offers":[{"title":"AES Ⅱ [03062004]","offer_id":68143113863453,"sku":null,"price":83.99,"currency_code":"USD","in_stock":true},{"title":"AES Ⅱ [03062004] with TEMS[04100427]","offer_id":68143113896221,"sku":null,"price":88.78,"currency_code":"USD","in_stock":true},{"title":"AES Ⅱ [03062004] with PT100[04100488]","offer_id":68143113928989,"sku":null,"price":93.58,"currency_code":"USD","in_stock":true},{"title":"AES Ⅱ [03062004] with Flow Meter[03040703]","offer_id":68143113961757,"sku":null,"price":116.38,"currency_code":"USD","in_stock":true},{"title":"AES Ⅱ [03062004] with TEMS[04100427] and Flow Meter[03040703]","offer_id":68143113994525,"sku":null,"price":121.16,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0742\/4013\/1357\/files\/AES-_-1.jpg?v=1795269101","url":"https:\/\/soarskyrc.com\/products\/frsky-advanced-engine-suite-ii-aes-ii-multi-functional-engine-management-box","provider":"SoarSky","version":"1.0","type":"link"}